Safety Warning — Overloading and Stacking Prohibited on Wall-Mounted Furniture
Safety Warning — Do Not Overload or Stack Items on Wall-Mounted Furniture
1. Purpose of this warning
This warning applies to furniture and units designed to be fixed to the wall, including storage units, wall-mounted base units, cabinets, shelves and modular living-room furniture.
A wall-mounted unit transfers the weight of its structure and everything placed inside or on its surface to the wall, the fasteners and its own joints. An excessive or concentrated load, or one applied dynamically, can cause panels to deform, hardware to fail, anchors to pull out or the entire unit to fall, posing a risk of personal injury and property damage.
You must not exceed the load capacity stated in the information or instructions for the specific product. Load capacity must not be inferred from the unit’s appearance or external dimensions, or from the fact that it appears stable after installation.
2. Do not exceed the load capacity
The total weight must include all items placed on, inside or hung from the unit, including appliances, mounts, books, dishes, devices, cables, accessories and containers.
Where separate load limits are specified for the top surface, compartment, shelf or drawer, each limit must be observed separately. Spare capacity in one part of the unit does not authorize exceeding the limit for another part.
If no verifiable load capacity is specified, do not place heavy items or appliances that generate vibration, heat or repeated stress on the unit. Before use, contact Weldexa for clarification about the information available for the model in question.
The stated load capacity assumes complete and correct installation on a compatible wall. It does not independently guarantee the strength of a wall, wall plug or fastening system selected without checking its suitability.
3. Do not stack items improperly
Do not stack heavy, unstable or irregularly shaped objects on the surface of a wall-mounted unit. Do not build tall stacks that could shift or topple, or increase leverage on the anchors.
Do not place objects on top of one another when:
a) the weight is concentrated in a small area;
b) the object’s base is not fully supported;
c) the stack could wobble when doors or drawers are opened;
d) any part extends beyond the edge;
e) the load could fall as a result of impacts, vibration or unintended movement;
f) the arrangement prevents inspection of the surface or fasteners.
Do not use boxes, books, appliances or other objects to create makeshift risers. The unit must not support other pieces of furniture that require their own fastening or structural support.
4. Distribute the load correctly
The permitted load must be distributed as evenly as possible. Heavier items should be placed close to the wall and, inside compartments, in the lowest positions compatible with the structure. Avoid concentrating loads on edges, corners, open doors or the front of shelves.
Opening doors and drawers temporarily shifts the center of gravity. Do not leave multiple parts open at the same time if this could increase instability or stress on the fasteners. Doors, drawers and pull-out shelves must not be used as additional support surfaces.
An object with narrow feet or a rigid base can exert high pressure even when its total weight does not seem significant. In this situation, check that the surface is suitable and that the load will not leave indentations, cause bending or damage the panel.
5. Prohibited stresses
A wall-mounted unit is not a seat, step, platform or support for people. It is prohibited to:
a) sit, climb, kneel or stand on the unit;
b) lean on it with your body weight;
c) pull on doors, drawers or shelves to lift yourself up;
d) use the unit as a support for ladders or equipment during household tasks;
e) hang bags, weights or other loads from handles or edges;
f) push, pull, shake or strike the structure;
g) allow children to climb, swing or play with moving parts.
Dynamic loads can briefly produce greater stresses than those caused by a static weight and may cause failure even when the nominal limit does not appear to have been exceeded.
6. Wall, fasteners and installation
Before installation, assess the wall’s material, thickness and condition, as well as the presence of cavities, utilities, coverings or damaged areas. Plasterboard, hollow masonry, concrete, stone and mixed structures require different fastening systems.
Installation must be carried out by a competent person using anchors compatible with the wall, the total weight and the available instructions. Wall plugs must not be selected solely on the basis of hole diameter or availability.
All specified fixing points must be used. Do not omit any, change their position, enlarge holes, cut brackets or replace hardware with components whose specifications have not been verified.
Before loading the unit, check its alignment, that the brackets are fully engaged, that safety devices are tight and that there is no gap between the unit and the wall. Add the load gradually, watching for any movement or deformation.
7. Appliances and special items
Televisions, audio equipment, electronic devices and other items with concentrated weight may be placed on the unit only if the intended use and load capacity of the specific unit expressly permit it.
Ventilation, heat dissipation, base stability and the pull exerted by cables must also be taken into account. Cables must not bear weight, pull the device toward the edge or interfere with doors and drawers.
Containers holding liquids, aquariums, very heavy vases and appliances that produce vibration must not be placed on wall-mounted units unless this use is expressly permitted. Moisture and leaks can weaken panels, joints and walls without producing any immediately visible signs.
8. Checks after installation
Check the unit after installation, whenever items are rearranged and periodically during use. Check for:
a) looseness or separation from the wall;
b) loose screws, brackets or joints;
c) cracks in the wall or around the anchors;
d) bending of surfaces and shelves;
e) deformation of panels, doors or drawers;
f) unusual noises during use;
g) variations in alignment;
h) traces of moisture, corrosion, or damage.
The checks must be repeated after work on the wall, impacts, significant vibrations, leaks, changes to the environment, or significant variations in the load.
9. Danger signs and immediate action
In the presence of movement, tilting, sudden noise, cracking, detachment, deformation, or loosening, the unit must not continue to be used.
When it can be done without exposing yourself to the risk of falling, objects must be removed starting with the most accessible and lightest. The area below must be kept clear and inaccessible to children and animals. An unstable element must not be attempted to be supported by hand.
Simply tightening a screw is not a sufficient solution if the wall, hole, or anchor is damaged. The system must be examined by a competent person before resuming use.
10. Children, animals, and thoroughfares
Wall-mounted units must not be installed or loaded in a way that creates a foreseeable risk in areas where children or animals may stay, run, or play.
Remote controls, toys, food, or other objects that may induce a child to climb must not be placed in positions reachable only by climbing on the unit. Dangling cables and protruding objects must be avoided.
Adult supervision does not replace proper installation nor authorize the use of the unit as a body support.
11. Modifications, disassembly, and reinstallation
Additional drilling, cutting, panel reduction, bracket relocation, replacement of fastening systems, or joining with other units may alter the load capacity and force distribution. Such interventions must not be carried out without an appropriate technical assessment.
After disassembly, wall plugs, holes, and fastening components must not be automatically reused. The new wall and all anchors must be checked as if it were a first installation. Deformed, corroded, or worn components must be replaced with compatible elements.
12. Liability and product defects
The customer is responsible for compliant use, respecting the indicated load capacity, ensuring proper load distribution, and adopting a fastening system suitable for the wall.
Weldexa is not liable for damages demonstrably caused by overloading, unstable stacking, climbing, unauthorized modification, unsuitable wall, incorrect anchoring, or installation contrary to the instructions.
This limitation does not exclude Weldexa's liability for original defects, incompatible components, insufficient instructions, or other product issues that contributed to the damage. The cause must be concretely assessed; the mere detachment of the unit does not automatically attribute liability to the customer.
13. Reporting problems
In the event of a damaged component, incompatible hardware, incorrect drilling, deformation, instability, or doubt about safety, installation or use must be suspended.
The report must indicate the order number, the affected component, a description of the problem, and, when possible, photographs of the whole, the fastenings, the wall, and the damaged area. The images must be limited to what is necessary and must not include people or data unrelated to the request.
The consumer retains the right to communicate withdrawal without reason within 30 calendar days from physical possession of the good. The exercise of withdrawal does not replace the immediate measures necessary to secure a unit showing signs of failure.
14. Contacts
Weldexa
Email: talkservice@weldexa.com
Phone: +1 910 218 0329
Address: 4407 Hopson Rd, Apt 8105, Morrisville, NC 27560
Customer service: Monday to Friday, from 09:30 to 17:30. The support channel is closed on Saturdays, Sundays, and holidays.